Skip to main content

What should my Daikin controller be set to?

The settings to change on your controller to ensure Havenwise works as well as possible

Written by Sam Bates

1. Hot water setpoint mode

  1. Go to the heat pump's indoor controller and open User profile. Choose Installer and enter the installer PIN, which defaults to 5678

  2. Go to Tank [5] → Setpoint mode [5.B] and change it from weather dependent to Fixed

2. Hot water hysteresis

  1. Go back to the Tank [5] screen.

  2. Open Hysteresis [5.9]. There are two Hysteresis options on this screen, so check the number. Leave [5.A] as it is.

  3. Change it to 5 and confirm. It may already be on this value - if it is, you don't need to change anything.

Finally, exit the installer menu, saving or restarting if prompted. Once that's done, re-open the Havenwise app and continue set up.