Daikin: How to update your controller software to 7.11.0

Updating the MMI2 or MMI2.5 controller on a Daikin Altherma 3 with a USB stick

Written by Sam Bates

Before you start

This guide updates the software on the controller (the MMI) of a Daikin Altherma 3 heat pump to version 7.11.0, using a USB stick. It applies to MMI2 and MMI2.5 controllers. It covers the controller software only, not the outdoor or indoor unit circuit boards, and is written for technically confident users.

Please read before you begin. You carry out this update at your own risk. Havenwise provides this guide for information only and is not responsible for any damage, loss of settings or data, loss of heating or hot water, or other cost or inconvenience that results from following it. The firmware is made and supplied by Daikin, not Havenwise. Updating your system yourself may affect your warranty, so check with Daikin or your installer first if this matters to you. If anything is unclear or does not behave as described, stop and contact a qualified installer.

The update can reset some settings. Back up your settings and data before you start (Step 2) and check them afterwards (Step 5). When you have finished, let Havenwise know so we can confirm we are still receiving your data (Step 6).

What you need

  • The update file from Daikin: MMI2_2.5_update_7.11.0.zip. It is a standard .zip file, so your computer opens it with no extra software.

  • A USB stick of 8 GB or less, formatted as FAT32. Larger sticks may not be recognised. A second stick is useful for your settings backup.

  • A computer to download, extract and copy the files.

  • About 30 minutes, at a time when you can do without heating and hot water briefly.

  • A phone camera to photograph your settings.

Step 1: Check the controller

  1. On the controller, go to Information > Info.

  2. Scroll down. Unit interface hardware should show MMI2 or MMI2.5. This guide works for both.

  3. Note the software version. It is also shown on the start screen when the controller powers up.

If the hardware shows MMI1, or the software version is 7.1.0, stop and contact Havenwise support before going further. If it already shows 7.11.0 or later, you do not need this update.

Step 2: Back up your settings and data

Record your energy data, operating hours and all settings before you update. Photos of each screen on your phone are enough.

Log in as installer:

  1. Go to User profile.

  2. Enter the code 5678 to switch to the advanced (installer) user level.

Energy data:

  1. Go to Information > Energy data.

  2. Open Electricity consumed and Heat produced and record both.

  3. Use the right dial to switch between heating, cooling, hot water and total. Use the left dial to switch between today, this week, this year and since installation.

Operating hours:

  1. Go to Information > Operating hours.

  2. Record the hours for the pump, compressor, backup heater and any other entries.

Settings:

  1. Go to Installer settings > Overview settings.

  2. Photograph every page of the parameter grid (codes 00 to 0E on each page). You will check these after the update.

Back up to USB where possible: If your controller offers an option to save its settings, or its current software, to a USB stick, use it and keep that stick safe. Not every controller version supports this, so take the photos above as well. Also keep a copy of the firmware package, in case you need to repeat the update.

Step 3: Prepare the USB stick

  1. Plug the USB stick (8 GB or less) into your computer.

  2. Format it as FAT32. On Windows: open the stick in File Explorer, choose Drive Tools > Format, set File system to FAT32 (Default) and click Start. On a Mac: use Disk Utility, choose Erase and the format MS-DOS (FAT).

  3. Extract MMI2_2.5_update_7.11.0.zip. On Windows, right-click it and choose Extract All. On a Mac, double-click it.

  4. Open the extracted folder. It should contain a firmware folder and the files config.cfg, config_mmi25.cfg and keys.

  5. Copy only the contents of that folder to the top level of the USB stick, not the folder itself.

  6. Eject the stick safely.

Step 4: Install the update

  1. Switch off the power to the indoor unit at its isolator or circuit breaker.

  2. Plug the USB stick into the USB socket of the controller. You do not need to remove the cover.

  3. Switch the power back on. The controller finds the stick and installs the update automatically. Do not switch off the power or remove the stick while it runs.

  4. When it has finished, the controller restarts and shows 7.11.0 on the start screen.

  5. Switch off the power, remove the USB stick and switch the power back on.

Step 5: Check your settings and test

  1. Log in as installer again (User profile, code 5678).

  2. Open Installer settings > Overview settings and compare every page with your photos from Step 2.

  3. Correct any parameter that has changed.

  4. When the controller asks you to restart the unit, do so.

  5. Run the system and check heating and hot water work as before.

  6. Log out of the installer level on the controller when you have finished.

Step 6: Let Havenwise know

When the update is done and the system is running normally, contact Havenwise support. Tell us the new software version shown on your controller. We will check that we are now receiving the return temperature from your heat pump, and confirm back to you.

Troubleshooting

Problem

What to check

The controller does not start the update

The stick is FAT32 and 8 GB or less; the files sit at the top level of the stick, not inside a folder; the power was off when you inserted the stick

The version did not change

Your controller is an MMI2 or MMI2.5, its software was not 7.1.0 (Step 1), and you used MMI2_2.5_update_7.11.0

Heating or hot water behaves differently

Compare the settings overview with your photos from Step 2 and correct any changed parameters

Anything else, or an error code

Do not repeat the update. Contact your installer or Havenwise support with the error code and your software version

Did this answer your question?